channels 4 range
P0207~ P0210 are used to define the function selection of the 4 analog output channels.
P0297~ P0300 are used to set amplitude adjustment of the 4 analog output channels.

4-5 Function parameters

Table 4-51 Auto tuning
ID
Parameter
P0591 Auto tuning mode
Auto tuning
P0592
execution status
Auto tuning no-load
P0593
running frequency
Auto tuning no-load
P0594
running time
Auto tuning simulate
P0595
stall running
frequency
Auto tuning simulate
P0596
stall running current
Auto tuning simulate
P0597
stall running time
Kp for Auto tuning
P0522
current controller
Ki for Auto tuning
P0523
current controller
P0598 Auto tuning result
Auto tuning simulate
P0600
stall running time
SLVC running speed
of mechanical
P1035
parameter
identification
Torque reference of
mechanical
P1036
parameter
identification
Min
Max
Unit
0
4
0
33000
0.01Hz
1
50
0
33000
0.01Hz
1
100
1
50
0
65535
0.01
0
65535
0.01
1
50
0
100
0
100
55
Default
0-Disable
1-Identification with
motor rotating
2-Identification
without motor
0
rotating
3-Use parameters
provided by motor
supplier
4-Use empirical
parameters
0
5000
s
5
5000
%
30
s
5
30
300
0
Waiting time from no
s
5
load mode to stall
mode
Percentage of motor
%
20
rated speed
Percentage of motor
%
5
rated torque
Description