D.4.8 Special Auxiliary Relays - Delta Electronics AC Motor Drive VFD-E User Manual

Vfd-e high performance/flexible options/micro type ac motor drives
Table of Contents

Advertisement

D.4.8 Special Auxiliary Relays

Special
M
Normally open contact (a contact). This contact is On when running and it is
M1000
On when the status is set to RUN.
Normally closed contact (b contact). This contact is Off in running and it is Off
M1001
when the status is set to RUN.
On only for 1 scan after RUN. Initial pulse is contact a. It will get positive
M1002
pulse in the RUN moment. Pulse width=scan period.
Off only for 1 scan after RUN. Initial pulse is contact a. It will get negative
M1003
pulse in the RUN moment. Pulse width=scan period.
M1004
Reserved
M1005
Fault indication of the AC motor drives
M1006
Output frequency is 0
M1007
The operation direction of AC motor drives (FWD: 0, REV: 1)
M1008
Reserved
M1009
Reserved
M1010
Reserved
M1011
10ms clock pulse, 5ms On/5ms Off
M1012
100ms clock pulse, 50ms On / 50ms Off
M1013
1s clock pulse, 0.5s On / 0.5s Off
M1014
1min clock pulse, 30s On / 30s Off
M1015
Frequency attained
M1016
Parameter read/write error
M1017
Succeed to write parameter
M1018
Enable high-speed counter function (When M1028=On)
M1019
Reserved
M1020
Zero flag
M1021
Borrow flag
M1022
Carry flag
M1023
Divisor is 0
M1024
Reserved
M1025
RUN(ON) / STOP(OFF) the AC motor drive
Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11
Appendix D How to Use PLC Function|
Function
Read(R)/
Write(W)
R
R
R
R
--
R
R
R
--
--
--
R
R
R
R
R
R
R
R
R
R
R
R
R
--
R/W