SRX210 Services Gateway Hardware
Related
Documentation
Changing the Reset Config Button Behavior on the SRX210 Services Gateway
Related
Documentation
154
Changing the Reset Config Button Behavior on the SRX210 Services Gateway on page 154
Monitoring the SRX210 Services Gateway Chassis Using the CLI on page 145
Monitoring the SRX210 Services Gateway Components Using LEDs on page 147
Monitoring the SRX210 Services Gateway Using Chassis Alarm Conditions on page 149
Monitoring the SRX210 Services Gateway Power System on page 152
Juniper Networks Technical Assistance Center on page 155
You can change the default operation of the Reset Config button by limiting how the
button resets the services gateway:
To prevent the Reset Config button from setting the device to the factory default
configuration and deleting all other configurations:
admin@host# set chassis config-button no-clear
You can still press and quickly release the button to reset it to the rescue configuration.
To prevent the Reset Config button from setting the device to the rescue configuration:
admin@host# set chassis config-button no-rescue
You can still press and hold the button for 15 seconds or more to reset the gateway to
the factory defaults.
To disable the button and prevent the device from resetting to either configuration:
admin@host# set chassis config-button no-clear no-rescue
The no-clear option prevents the Reset Config button from deleting all configurations
on the services gateway. The no-rescue option prevents the Reset Config button from
loading the rescue configuration.
To return the function of the Reset Config button to its default behavior, remove the
config-button statement from the device configuration.
Using the Reset Config Button on the SRX210 Services Gateway on page 153
Monitoring the SRX210 Services Gateway Chassis Using the CLI on page 145
Monitoring the SRX210 Services Gateway Components Using LEDs on page 147
Monitoring the SRX210 Services Gateway Using Chassis Alarm Conditions on page 149
Monitoring the SRX210 Services Gateway Power System on page 152
Juniper Networks Technical Assistance Center on page 155
Copyright © 2012, Juniper Networks, Inc.

Advertisement

Table of Contents
loading

Table of Contents