Connect Power to an AC-Powered Services Gateway

WARNING: The device must be properly grounded before you connect the AC power
cords.
1.
2.
3.
NOTE: Each power supply must be connected to a dedicated AC power feed and a
dedicated external circuit breaker. We recommend that you use a 15 A (250 VAC)
minimum, or as permitted by local code.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and
connect the strap to one of the ESD points on the chassis. For more information
about ESD, see the SRX 5600 Services Gateway Hardware Guide.
Locate the power cords shipped with the device, which should have a plug
appropriate for your geographical location. See the SRX 5600 Services Gateway
Hardware Guide.
For each power supply:
Move the power switch on the power supply faceplate to the
a.
(
O
).
Insert the appliance coupler end of the power cord into the appliance inlet
b.
on the power supply.
Insert the power cord plug into an external AC power source receptacle.
c.
Dress the power cord appropriately. Verify that the power cord does not
d.
block the air exhaust and access to device components, or drape where
people could trip on it.