Packing the SRX210 Services Gateway and Components for Shipment
Packing the Services Gateway
Packing the Components for Shipment
Copyright © 2012, Juniper Networks, Inc.
This topic includes the following sections:
Packing the Services Gateway on page 161
Packing the Components for Shipment on page 161
To pack the services gateway for shipment:
Retrieve the shipping carton and packing materials in which the device was originally
1.
shipped. If you do not have these materials, contact your Juniper Networks
representative about approved packaging materials.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect
2.
the strap to the ESD point on the chassis or to an outside ESD point if the device is
disconnected from earth ground.
On the console or other management device connected to the services gateway, enter
3.
CLI operational mode and issue the following command to shut down the services
gateway software:
user@host> request system power-off
Wait until a message appears on the console confirming that the operating system
has halted.
Shut down power to the device by pressing the Power button on the front panel of
4.
the device.
Disconnect power from the device.
5.
Remove the cables that connect to all external devices.
6.
Remove all field-replaceable units (FRUs) from the device.
7.
If the device is installed on a wall or rack, have one person support the weight of the
8.
device while another person unscrews and removes the mounting screws.
Place the device in the shipping carton.
9.
Cover the device with an ESD bag, and place the packing foam on top of and around
10.
the device.
Replace the accessory box on top of the packing foam.
11.
Securely tape the box closed.
12.
Write the Return Materials Authorization (RMA) number on the exterior of the box to
13.
ensure proper tracking.
Follow these guidelines for packing and shipping individual components of the services
gateway:
Chapter 23: Returning the Services Gateway