SRX210 Services Gateway Electrical and Power Requirements

42
If you are mounting the device in a rack with other equipment, or if you are placing it
on the desktop near other equipment, ensure that the exhaust from other equipment
does not blow into the intake vents of the chassis.
Table 19 on page 42
provides information on the clearance requirements for maintaining
the optimum airflow and the distances for facilitating easy maintenance of the device.

Table 19: Clearance Requirements for the Services Gateway

Location
Front of the chassis
Rear of the chassis
Between front-mounting flange
and rack or cabinet edge
Between side of the chassis and
any non-heat-producing
surface such as a wall or
cabinet side
Between side of the chassis and
devices that have fans or
blowers
SRX210 Services Gateway Description on page 3
General Site Guidelines for Installing the SRX210 Services Gateway on page 39
Site Preparation Checklist for the SRX210 Services Gateway on page 37
SRX210 Services Gateway Cabinet Requirements on page 39
SRX210 Services Gateway Rack Requirements on page 40
There are factors you must consider while planning the electrical wiring and power
availability at your site. These factors include the following requirements:
Power specifications and requirements for the device
Electrical wiring guidelines for the device installation site
Recommended
Clearance
Requirement for Clearance
2.5 in. (6.35 cm)
Space for service personnel to
remove and install hardware
components
NOTE:
installing and removing Mini-PIMs.
2.5 in. (6.35 cm)
Space for service personnel to
remove and install hardware
components
2.5 in. (6.35 cm)
Space for cable management and
organization
2.5 in. (6.35 cm)
Space for the cooling system to
function properly and to maintain
unrestricted airflow around the
chassis
2.5 in. (6.35 cm)
Space for the cooling system to
function properly and to maintain
unrestricted airflow around the
chassis
Copyright © 2012, Juniper Networks, Inc.
More space is required for