Xerox DocuPrint 96 Message Manual page 38

Laser printing system
Hide thumbs Also See for DocuPrint 96:
Table of Contents

Advertisement

HIP (HOST INTERFACE PROCESSOR) MESSAGES
4-16
HP9420
Host not communicating. See host for reason
The HIP DIAGNOSTIC command was entered. The system failed
Test 1: (see explanation for message HP9400) or Test 2: system was
unable to send a command on OEMI and in turn read the printer
status.
Action
1. If Test 2 failed, diagnostics are terminated.
2. Inspect the 871-CM display (the "host" referred to in the
message) to learn nature of the failure.
3. Contact Xerox Customer Service and give information
appearing on the 871-CM display
HP9430
Host timed out in test 3. See host for reason
HIP diagnostic failed.
Action
1. Reenter the HIP DIAGNOSTIC command to retry the diagnostic
test.
2. If the problem recurs, contact your systems specialist or Xerox
Customer Service.
HP9431
Line no. n is open
The HIP DIAGNOSTIC command was entered. The system failed
Test 3 which verifies integrity of 8 parallel data lines. The line number
indicated is shorted high.
Action
1. Inspect the 871-CM display (the "host" referred to in the
message) to learn the nature of the failure.
2. Contact Xerox Customer Service and give information
appearing on the 871-CM display and in this message.
HP9432
Line no. n is shorted
The HIP DIAGNOSTIC command was entered. The system failed
Test 3 which verifies integrity of 8 parallel data lines. The line number
indicated is shorted to ground.
Action
1. Inspect the 871-CM display (the "host" referred to in the
message) to learn the nature of the failure.
2. Contact Xerox Customer Service and give information
appearing on the 871-CM display and in this message.
XEROX DOCUPRINT 96/DOCUPRINT 96MX LPS MESSAGE GUIDE