Toro Greensmaster 1018 Service Manual page 143

Hide thumbs Also See for Greensmaster 1018:
Table of Contents

Advertisement

Installing the Bedbar (continued)
Greensmaster
®
1018/1021/1026
18238SL Rev B
7. Install the bedbar bolt assemblies (8). Make sure that the washers are not
caught on the threads of the pivot bolts. Torque tighten each bedbar bolt (8)
from 22 to 27 N∙m (190 to 240 in-lb).
Do not over tighten the lock nuts as this can distort the side plates
and affect reel bearing alignment. When the lock nut is correctly
tightened, the inside washers may be loose.
8. Tighten both lock nuts (9) until outside metal washers do not have any end
play and can still can be rotated.
9. Tighten the nut (19) on each bedbar adjuster assembly (16) until the adjuster
spring (18) is fully compressed, then loosen the nut (19) to 1/2 turn.
10. Adjust the bedknife to reel contact; refer to the Cutting Unit Operator's
Manual.
11. Attach the spark plug wire to the engine spark plug.
IMPORTANT
Page 8–9