Removing the Bedbar
Greensmaster
®
1018/1021/1026
18238SL Rev B
Note: Refer to
Figure 70
1. Park the machine on a level surface. Ensure that the engine is OFF and
the traction control is in NEUTRAL.
2. Remove the spark plug wire from the engine spark plug.
3. Loosen the nuts (19) on the end of each bedbar adjuster assembly (3) until
the washer (17) is loose.
4. Loosen the locknuts (9) on each bedbar bolt (8).
5. Remove the 2 bedbar bolts (8), 2 flat washers (7) and 4 plastic washers (6
and 15) from the cutting unit side plates (1).
Contact with the reel, bedknife or other cutting unit parts can result
in personal injury. Use heavy gloves when handling the bedbar.
6. Remove the bedbar assembly (6) from the cutting unit.
7. Inspect the nylon bushings (5) and rubber bushings (4) in the side plates for
wear or damage. Replace the bushings if necessary.
during this procedure.