Parker EME
3.11.3.4
Emergency power-off and protective door monitoring without
safety switching devices
With Compax3M, a 2-channel protective door monitoring switch or a 2 channel
emergency power-off switch can be directly connected. The figure below visualizes
an application with 2 channel protective door monitoring switch.
The Compax3M drive modules with Compax3MPxx mains rectifier must be located
in a protected area (IP54 control cabinet). Outside this protected area, the line
guiding to the external switches must be separated channelwise or must be espe-
cially protected (screened).
It is also permitted to use one acknowledgement switch for both servo drives at a
time. In both cases the acknowledgement does only correspond to category B (no
longer category 3), therefore this acknowledgement should not be used if there is
any possibility of stepping in the dangerous area. In this case, an external acknow-
ledgement device must be used.
Compax3M
Compax3M
192-120114 N5 C3I22T11 June 2008
X3
Quit
Energize
X14.1
X14.2
X14.3
X14.4
X3
Quit
Energize
X14.1
X14.2
X14.3
X14.4
GND24
Compax3 device description
motor
Gefahrenbereich
Danger Zone
motor
Schutztür offen
Safety door open
S1
S2
+24V
97