Parker EME
4.3.2.
Scope
In this chapter you can read about:
Monitor information...........................................................................................................161
User interface ...................................................................................................................162
Example: Setting the Oscilloscope...................................................................................167
4.3.2.1
The integrated oscilloscope function features a 4-channel oscilloscope for the dis-
play and measurement of signal images (digital and analog) consisting of a graphic
display and a user interface.
Special feature:
in the single mode you can close the ServoManager after the activation of the me-
asurement and disconnect the PC from Compax3 and upload the measurement
into the ServoManager later.
Monitor information
1: Display of the trigger information
2: Display of the operating mode and the zoom setting
2a: Green indicates, that a measurement is active (a measurement can be star-
ted or stopped by clicking here).
2b: Active channel: the active channel can be changed sequentially by clicking
here (only with valid signal source).
3: Trigger point for Single and Normal operating mode
4: Channel information: Type of display and trigger settiing
5: X-DIV: X deviation set
6: Single channel sources
192-120114 N5 C3I22T11 June 2008
Setting up Compax3
161