Temperature Switch Compax3Mp (Mains Module) - Parker Compax3 Series Operating Instructions Manual

Electromechanical automation, positioning via devicenet
Hide thumbs Also See for Compax3 Series:
Table of Contents

Advertisement

Compax3 device description
3.5.7.1
3.5.8.
Motor / motor brake Compax3M (axis controller)
48

Temperature switch Compax3MP (mains module)

Connector X40 Pin T1R, T2R
Temperature monitoring:
The temperature switch (normally closed contact) must be connected, unless an
error message will be issued.
Temperature switch/relay
No galvanic separation, the temperature sensor (normally closed contact) must
comply with the safe separation according to EN 60664.
If there is no temperature monitoring due to the connected braking resistor, the
T1R and T2R connections must be connected by a jumper.
Without temperature monitoring, the braking resistor might be destroyed.
Connector X43
PIN
Designation
BR+
Motor holding brake *
BR-
Motor holding brake *
PE
PE (motor)
W
W (motor)
V
V (motor)
U
U (motor)
* Please note that Compax3 will report the error "open circuit at holding
brake" (5481h / 2163d) if the current is < 150mA.
192-120114 N5 C3I22T11 June 2008
C3I22T11

Hide quick links: