Compax3 device description
3.11.2.3
92

Technical details of the Compax3M S1 option

Compax3M S1 Option: Signal inputs for connector X14
Nominal voltage of the
inputs
Required isolation of the
24V control voltage
Protection of the STO
control voltage
Number of inputs
Signal inputs via opto-
coupler
STO1/
STO2/
Switch-off time with une-
qual input statuses (max.
reaction time)
Grouping of safety level
192-120114 N5 C3I22T11 June 2008
24V
Grounded protective extra low voltage, PELV
1A
2
Low = 0...7V DC or open
High = 15...30V DC
I
at 24V DC: 8mA
in
Low = STO activated
High = STO deactivated
Low = STO activated
High = STO deactivated
20 seconds
Category 3
PL=d
PFH=1.01 x 10-7h-1
C3I22T11