Compax3 device description
3.6.5.

Control voltage 24 VDC C3H

56
Connector
Description
X4 Pin
1
NC
2
Gnd 24 V
3
+24V
Control voltage 24VDC Compax3S and Compax3H
Controller type
Voltage range
Mains module
Fuse
Current drain of the device
Total current drain
Ripple
Requirement according to safe extra
low voltage (SELV)
Short-circuit proof
192-120114 N5 C3I22T11 June 2008
NC
GND
24 VDC (power supply)
Compax3
21 - 27VDC
with switch-on current limitation, due to capaci-
tive load
MCB miniature circuit breaker or "delayed ac-
tion fuse", due to capacitive load
0.8A
0.8 A + Total load of the digital outputs + cur-
rent for the motor holding brake
0.5Vpp
yes
conditional (internally protected with 3.15AT)
C3I22T11