Compax3 device description
3. Compax3 device description
3.1
Meaning of the status LEDs - Compax3 axis controller
Note on Compax3H:
26
Connections of Compax3S.................................................................................................28
Connections of Compax3H ................................................................................................50
Communication interfaces ..................................................................................................60
Signal interfaces .................................................................................................................65
Device status LEDs
Voltages missing
During the booting sequence
No configuration present.
SinCos
feedback not detected.
©
Compax3 IEC61131-3 program not compatible
with Compax3 Firmware.
no Compax3 IEC61131-3 program
For F12: Hall signals invalid.
Axis without current excitation
Power supplied to axis; commutation calibration
running
Axis with current excitation
Axis in fault status / fault present / axis energized
(error reaction 1)
Axis in fault status / fault present / axis deenergized
(error reaction 2)
Compax3 faulty: Please contact us.
The internal device status LEDs are only connected to the external housing LEDs,
if the RS232 jumper at X10 is fitted to the control and the upper dummy cover is
fitted.
192-120114 N5 C3I22T11 June 2008
Right LED (red)
Left LED (green)
off
off
alternately flashing
Flashes slowly
off
off
Flashes slowly
off
Flashes quickly
off
on
Flashes quickly
on
on
off
on
on
C3I22T11