Conditions Of Utilization; Conditions Of Utilization For Ce-Conform Operation - Parker Compax3 Series Operating Instructions Manual

Electromechanical automation, positioning via devicenet
Hide thumbs Also See for Compax3 Series:
Table of Contents

Advertisement

Introduction
1.6

Conditions of utilization

In this chapter you can read about:

Conditions of utilization for CE-conform operation .............................................................16

Conditions of utilization for UL certification Compax3S......................................................19
Conditions of utilization for UL certification Compax3M .....................................................21
Current on the mains PE (leakage current) ........................................................................22
Supply networks .................................................................................................................23
1.6.1.
Conditions of utilization for CE-conform operation
Mains filter:
16
- Industry and trade -
The EC guidelines for electromagnetic compatibility 2006/95/EC and for electrical
operating devices for utilization within certain voltage limits 2004/108/EC are fulfil-
led when the following boundary conditions are observed:
Operation of the devices only in the condition in which they were delivered,
In order to ensure contact protection, all mating plugs must be present on the devi-
ce connections even if they are not wired.
A mains filter is required in the mains input line if the motor cable exceeds a certain
length. Filtering can be provided centrally at the plant mains input or separately at
the mains input to each device or with C3M for each axis combination.
Devices in a commercial and residential area (limit values of Class C2 in ac-
cordance with EN 61800-3)
The following mains filters are available for independent utilization:
Device: Compax3
S0xxV2
S1xxV2,
S0xxV4, S150V4
S300V4
Device: Compax3
H050V4
H090V4
H1xxV4
Industrial area (limit values class C3 in accordance with EN 61800-3)
Longer motor cable lengths are possible in industrial areas.
Devices in the industrial area (limit values class C3 in accordance with EN
61800-3)
The following mains filters are available for independent utilization:
Device: Compax3
MP10
MP10
MP20
192-120114 N5 C3I22T11 June 2008
i.e. with all housing panels.
Order No.:
Condition:
NFI01/01
Only for motor lines > 10m
NFI01/02
Only for motor lines > 10m
NFI01/03
independent of the length of the
motor cable (always required)
Order No.:
Condition:
NFI02/01
Only for motor lines > 10m
NFI02/02
Only for motor lines > 10m
NFI02/03
Only for motor lines > 10m
Order No.:
Condition:
NFI03/01
Reference axis combination 6x10m
NFI03/02
Reference axis combination 6x50m
NFI03/03
Reference axis combination 6x50m
C3I22T11