4.1.7.3

Travel Limit Settings

Software end limits
The error reaction when reaching the software end limits can be set:
Possible settings for the error reaction are:
No response
downramp / stop
Downramp / switch to currentless (standard setting)
If "no reaction" was set, no software limits must be entered.
Software end limits:
The travel range is defined via the negative and positive end limits.
0
1
2
1: negative end limit
2: positive end limit
Software end limit in absolute operating mode
The positioning is restricted to the range between the travel limits.
A positioning order aiming at a target outside the travel range is not executed.
1
V
1: negative end limit
2: positive end limit
The reference is the position reference point that was defined with the machine
reference and the machine reference offset.
Software end limits in reset mode
The reset mode does not support software end limits
192-120114 N5 C3I22T11 June 2008
2