Setting up Compax3
118

With direction reversal switches

In this chapter you can read about:
MN-M 1, 2: Limit switch as machine zero ........................................................................ 126
MN-M 132, 133: Determine absolute position via distance coding with direction reversal switches
......................................................................................................................................... 127
In this chapter you can read about:
MN-M 7...10: Direction reversal switches on the positive side ........................................ 122
MN-M 11...14: With direction reversal switches on the negative side ............................. 122
In this chapter you can read about:
MN-M 23...26: Direction reversal switches on the positive side ...................................... 118
MN-M 27...30: With direction reversal switches on the negative side ............................. 119
Machine zero modes with a home switch which is activated in the middle of the
travel range and can be deactivated to both sides.
The assignment of the direction reversal switches (see page 132) can be
changed.
Function Reversal via Current threshold
If no direction reversal switches are available, the reversal of direction can also be
performed during the machine zero run via the function "direction reversal via Cur-
rent threshold"
Here the drive runs towards the mechanical limit mounted at the end of the travel
range.
When the settable Current threshold is reached, the drive is braked and changes
the travel direction.
Caution!
Wrong settings can cause hazard for man and machine.
It is therefore essential to respect the following:
Choose a low machine zero speed.
Set the machine zero acceleration to a high value, so that the drive changes di-
rection quickly, the value must, however, not be so high that the limit threshold is
already reached by accelerating or decelerating (without mechanical limitation).
The mechanical limitation as well as the load drain must be set so that they can
absorb the resulting kinetic energy.
MN-M 23...26: Direction reversal switches on the positive side
Without motor zero point, with direction reversal switches
24
23
23
24
23
24
1
2
1: Logic state of the home switch
2: Logic state of the direction reversal switch
192-120114 N5 C3I22T11 June 2008
26
25
26
25
25