3.2
Meaning of the status LEDs - Compax3MP (mains
module)
C3MP Status LEDs
Control voltage 24 VDC iss missing**
Error of mains module*
DC power voltage is built up
Phase failure / mains power supply undervoltage
Address assignment CPU active
Address assignment CPU completed
C3MPxx Ready - State
Incorrect wiring of internal communication X30/31
*can be read out in each axis controller
Caution!
When the control voltage is missing there is no indication whether or
not high voltage supply is available.
192-120114 N5 C3I22T11 June 2008
Compax3 device description
Left LED (green)
Right LED (red)
off
off
off
on
-
Flashes quickly
on
Flashes slowly
Flashes quickly
-
Flashes slowly
-
on
off
Flashes slowly
Flashes quickly