Compax3 device description
3.7.3.2
64

Function of the Bus LEDs

LED (red)
No. Signal
1
off
2
Single flash
3
Double flash
4
Triple flash
5
on
If several errors occur at once, the error with the most significant number is repor-
ted.
LED green
Signal
Status
Single flash
On-line
Not Connec-
ted
blinks (permanently)
On-line
Connected
on
On-line
I/O Connected
Single flash
On
200ms
Off
Double flash
On
200ms 200ms
Off
Triple flash
On
200ms 200ms
Off
192-120114 N5 C3I22T11 June 2008
Status
Description
No Error
The bus is operating
Warning
at least one of the error counters of the CAN
controller has reached the warning level.
Error
Communication Fault
Error
Double Mac ID
Error
Bus Off
Description
Online, not at the master (not allocated)
Online, at the master (allocated)
I/O Messages allocated
1s
1s
1s