Braking Resistor - Parker Compax3 Series Operating Instructions Manual

Electromechanical automation, positioning via devicenet
Hide thumbs Also See for Compax3 Series:
Table of Contents

Advertisement

Setting up Compax3
4.1.5.

Braking Resistor

106
Compax3MxxxD6 at 3*480VAC
Switching fre-
quency*
8kHz
I
nominal
I
peak
(<5s)
16kHz
I
nominal
I
peak
(<5s)
32kHz
I
nominal
I
peak
(<5s)
The values marked with grey are the pre-set values (standard values)!
*corresponds to the frequency of the motor current
If the regenerative brake output exceeds the amount storable energy of the servo
controller (see page 401), an error will be generated. To ensure safe operation, it
is then necessary to either
reduce the accelerations resp. the decelerations,
or you will need an external braking resistor (see page 363) .
Please select the connected braking resistor or enter the characteristic values of
your braking resistor directly.
Please note that with resistance values greater than specified, the power
output from the servo drive can no longer be dissipated in the braking
192-120114 N5 C3I22T11 June 2008
M050D6 M100D6 M150D6
4A
8A
12.5A
eff
eff
8A
16A
25A
eff
eff
eff
3A
5.5A
8A
eff
eff
eff
6A
11A
16A
eff
eff
eff
2A
2.5A
4A
eff
eff
eff
4A
5A
8A
eff
eff
eff
resistor.
C3I22T11
M300D6
25A
eff
eff
50A
eff
15A
eff
30A
eff
8.5A
eff
17A
eff