Mode 2: Compax3 Input Values Are Deduced From Times And Maximum Values - Parker Compax3 Series Operating Instructions Manual

Electromechanical automation, positioning via devicenet
Hide thumbs Also See for Compax3 Series:
Table of Contents

Advertisement

Setting up Compax3
4.3.10.2
286
Mode 2: Compax3 input values are deduced from times and
maximum values
A jerk-limited motion profile is calculated from the positioning time and the maxi-
mum speed / acceleration
As a result you will get, besides a graphical display, the following characteristic
values of the profile:
the parameters Position, Speed, Acceleration, Deceleration, Acceleration Jerk
and Deceleration Jerk
Times for the acceleration, deceleration and constant phase
Maximum values for acceleration, deceleration and speed
Set deceleration and acceleration phase
The profile can be defined more exactly by entering the segmentation into decele-
ration and acceleration phase.
When setting 50% and 50%, a symmetrical design will result, the values for trian-
gular operation are calculated, which is limited by the maximum speed.
The total of the percentage values may not exceed 100.
The percentage entries refer to the total positioning time.
Example:
35%
192-120114 N5 C3I22T11 June 2008
30%
100%