3.3.5.

C3Sxxx V2

In this chapter you can read about:

Main voltage supply C3S connector X1 .............................................................................33

Braking resistor / high voltage DC C3S connector X2........................................................34
3.3.5.1
Device protection
Main voltage supply C3S connector X1
In this chapter you can read about:
Power supply plug X1 for 1 AC 230VAC/240VAC devices................................................ 33
Power supply plug X1 for 3AC 230VAC/240VAC devices................................................. 33
By cyclically switching on and off the power voltage, the input current limita-
tion can be overloaded, which will cause a device error.
Therefore please wait at least 2 minutes after switching off before you switch
Power supply plug X1 for 1 AC 230VAC/240VAC devices
PIN
Designation
1
L
2
N
3
PE
Mains connection Compax3S0xxV2 1AC
Controller type
Supply voltage
Input current
Maximum fuse rating per device
(=short circuit rating)
Always switch devices off before wiring them!
Dangerous voltages are still present until 5 minutes after switching
off the power supply!
Power supply plug X1 for 3AC 230VAC/240VAC devices
PIN
Designation
1
L1
2
L2
3
L3
4
PE
192-120114 N5 C3I22T11 June 2008
the device on again!
S025V2
Single phase 230VAC/240VAC
80-253 VAC/50-60Hz
6Aeff
10 A (MCB miniature
circuit breaker)
Compax3 device description
S063V2
13Aeff
16 A (MCB miniature
circuit breaker)