Compax3 device description
3.7

Communication interfaces

In this chapter you can read about:
RS232 / RS485 interface (plug X10) ..................................................................................60
Communikation Compax3M ...............................................................................................61
DeviceNet connector X23 ..................................................................................................63
3.7.1.
RS232 / RS485 interface (plug X10)
60
Interface selectable by contact functions assignment of X10/1:
X10/1=0V RS232
X10/1=5V RS485
PIN
RS232 (Sub D)
X10
1
(Enable RS232) 0V
2
RxD
3
TxD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
+5V
RS485 2-wire
PIN
RS485 two wire (Sub D)
X10
Pin 1 and 9 jumpered externally
1
Enable RS485 (+5V)
2
res.
3
TxD_RxD/
4
res.
5
GND
6
res.
7
TxD_RxD
8
res.
9
+5V
RS485 4-wire
PIN
RS485 four wire (Sub D)
X10
Pin 1 and 9 externally jumpered
1
Enable RS485 (+5V)
2
RxD
3
TxD/
4
res.
5
GND
6
res.
7
TxD
8
RxD/
9
+5V
USB - RS232/RS485 converter
The following USB - RS232 converters were tested:
ATEN UC 232A
USB GMUS-03 (available under several company names)
USB / RS485: Moxa Uport 1130 http://www.moxa.com/product/UPort_1130.htm
Ethernet/RS232/RS485: NetCom 113 http://www.vscom.de/666.htm