Braking Resistor / High Voltage Supply Connector X2 For 3Ac 400Vac/480Vac_C3S Devices - Parker Compax3 Series Operating Instructions Manual

Electromechanical automation, positioning via devicenet
Hide thumbs Also See for Compax3 Series:
Table of Contents

Advertisement

Parker EME
3.3.6.2
Braking resistor / high voltage supply connector X2 for 3AC
400VAC/480VAC_C3S devices
PIN
Description
1
+ Braking resistor
2
- Braking resistor
3
PE
4
+ DC high voltage supply
5
- DC high voltage supply
Braking operation Compax3SxxxV4 3AC
Controller type
Capacitance / storable
energy
Minimum braking- resistan-
ce
Recommended nominal
power rating
Maximum continuous cur-
rent
Connection of a braking resistor
Mimimum line cross section:
Maximum line length:
Maximum output voltage:
192-120114 N5 C3I22T11 June 2008
no short-circuit protec-
tion!
S015V4
S038V4
S075V4
235μF /
235μF /
470μF /
37Ws
37Ws
75Ws
100Ω
100Ω
56Ω
60 ...
60 ...
60 ... 500
100W
250W
W
10A
10A
15A
1.5mm
2
2m
800VDC
Compax3 device description
S150V4
S300V4
690μF /
1100μF /
110Ws
176Ws
33Ω
15Ω
60 ... 1000
60 ... 1000
W
W
20A
30A
37