Setting up Compax3

4.1.14. Write into set table

Machine reference
run
4.1.14.1
Definition of the
pattern:
144
The motion sets are stored in a set table.
The table rows define always one motion set, in the columns the respective motion
parameters of a motion set are stored.
Motion parameters
Machine reference
run
Set 1
set no. 2
...
Set 31
exact description (see page 315).
31 motion sets are possible.
The motion set to be executed is selected via Status word 2.
For the motion sets different motion functions with different motion parameters are
available:
empty motion set
Empty:
absolute positioning
MoveAbs (see
page 145):
relative Positioning
MoveRel (see
page 145):
electronic gearbox
Gearing (see pa-
ge 151):
Registration mark-related positioning
RegSearch (see
(uses 2 motion sets: RegSearch and RegMove)
page 146):
velocity control
Velocity (see pa-
ge 152):
Stop movement
Stop:
For each motion set you can define programmable status bits (PSBs), which will
then be put out after the termination of the motion set.
A start signal at address = 0 (motion set 0) triggers a machine zero run.

Programmable status bits (PSBs)

The successful execution of a motion set can be queried via the PSBs.
PSBs: Bit 12, 13 and 14 of status word 2.
The settings for the PSBs are made in the respective motion set
You can set 3 assignments for the respective bits:
X: No change
Output / Bit is not influenced
0: Inactive
Output / Bit is set to 0
1: Active
Output / Bit is set to 1 resp. 24VDC
Storage of the PSBs (see page 315).