3.5.2.

Connections on the device bottom

Always switch devices off before wiring them!
Dangerous voltages are still present until 5 minutes after switching
off the power supply!
Caution!
When the control voltage is missing there is no indication whether or not
high voltage supply is available.
PE connection
The PE connection is made with 10mm
tom of the device.
Attention hot surface!
The heat dissipator can reach very high temperatures (>70°C)
MP
X40
X41
1
4
M
X43
2
4
3
Line cross-sections of the power connections (on the device bottoms)
Compax3 device:
Cross-section: Minimum... Maximum[mm
ve]
M050, M100, M150
0,25 ... 4 (AWG: 23 ... 11)
M300
0,5 ... 6 (AWG: 20 ... 10)
MP10
Mains supply: 0,5 ... 6 (AWG: 20 ... 10)
Braking resistor: 0,25 ... 4 (AWG: 23 ... 11)
MP20
Mains supply: 0,5 ... 16 (AWG: 20 ... 6)
Braking resistor: 0,25 ... 4 (AWG: 23 ... 11)
192-120114 N5 C3I22T11 June 2008
via a grounding screw at the bot-
2
Power module
Braking Resistor
Mains supply VAC/PE
Central ground connection for the axis combination,
with 10mm
to the ground screw on the housing.
2
Fan*
Axis controller
Motor / Brake
Fixing for motor shield clamp
Fan*
optinally, the axis controller features a ground screw
on the housing, if the grounding is not possible via the
back plate.
* is internally supplied.