3.7.2.

Communikation Compax3M

In this chapter you can read about:
PC - Compax3MP (mains module).....................................................................................61
Communication in the axis combination (connector X30, X31)..........................................61
Adjusting the basic address ...............................................................................................62
Setting the axis function .....................................................................................................62
3.7.2.1
3.7.2.2
PC - Compax3MP (mains module)
Connector X3
USB2.0
Connect your PC to the USB sleeve X3 of the mains module via an USB cable
(SSK33/03).
Communication in the axis combination (connector X30, X31)
The communication in the axis combination is implemented via a SSK28 cable and
double RJ45 sleeves on the device top.
Beginning with the Compax3MP (mains module) the connection is always made
from X30 to X31 of the next device. On the first device (X31) and the last device
(X30) in the multi-axis combination, a bus termination plug (BUS07/01) is required.
Orientation to the back
side
Orientation to the front
plate
192-120114 N5 C3I22T11 June 2008
Compax3MP (mains module)
X30
out
X31
in
res.
Reserved
Compax3M (axis)
X30
out
X31
in
res.
Reserved
Compax3 device description