Parker EME
3.5.5.

Control voltage 24 VDC C3H

Connector
Description
X4 Pin
1
NC
2
Gnd 24 V
3
+24V
Control voltage 24VDC Compax3S and Compax3H
Controller type
Voltage range
Mains module
Fuse
Current drain of the device
Total current drain
Ripple
Requirement according to safe extra
low voltage (SELV)
Short-circuit proof
192-120101 N11 C3I11T11 November 2007
NC
GND
24 VDC (power supply)
Compax3
21 - 27VDC
with switch-on current limitation, due to
capacitive load
MTP miniature circuit breaker or "delayed action
fuse", due to capacitive load
0.8A
0.8 A + Total load of the digital outputs +
current for the motor holding brake
0.5Vpp
yes
conditional (internally protected with 3.15AT)