Braking Resistor / Temperature Switch Compax3Mp (Mains Module) - Parker Compax3S025V2 Operating Instructions Manual

Compax3 i11t11 positioning via digital i/os
Hide thumbs Also See for Compax3S025V2:
Table of Contents

Advertisement

Compax3 device description
Caution!
3.4.7.
Braking resistor / temperature switch Compax3MP (mains
module)
40
Mains connection Compax3MP10D6
Device type Compax3
Supply voltage
Input current
Maximum fuse rating per device
(=short circuit rating)
The Compax3MP10D6 devices must only be operated with three phases!
Always switch devices off before wiring them!
Dangerous voltages are still present until 5 minutes after
switching off the power supply!
The energy generated during braking operation must be dissipated via a braking
resistor.
Connector X40
PIN
Description
+R
+ Braking resistor
-R
- Braking resistor
PE
PE
T1R
Temperature Switch
T2R
Temperature Switch
Braking operation Compax3MP10D6 (mains module)
Device type Compax3
Capacitance / storable energy
Minimum braking- resistance
Recommended nominal power rating
Pulse power rating for 1s
Maximum permissible continuous current
Braking operation Compax3MxxxD6 (axis controller)
Device type Compax3
Capacitance / storable energy
192-120101 N11 C3I11T11 November 2007
MP10
Rated voltage 3AC 400V
230-480VAC ±10% / 50-60Hz
22Aeff
25A
MTP miniature circuit breaker (ABB)
Recommendation: S203-K25
no short-circuit
protection!
MP10
550µF/
92Ws at 400V
53Ws at 480V
27Ω
500 ... 1500W
22kW
13A
M050
M100
110µF/
220µF/
18Ws at 400V
37Ws at 400V
10Ws at 480V
21Ws at 480V
Positioning via digital I/Os
M150
220µF/
37Ws at 400V
21Ws at 480V

Advertisement