Parker EME
3.4.2.
Connections on the device bottom
Always switch devices off before wiring them!
Dangerous voltages are still present until 5 minutes after
switching off the power supply!
Caution!
When the control voltage is missing there is no indication whether or
not high voltage supply is available.
PE connection
The PE connection is made with 10mm
bottom of the device.
Attention hot surface!
The heat dissipator can reach very high temperatures (>70°C)
MP
X40
X41
1
4
M
X43
2
4
3
Line cross-sections of the power connections (on the device bottoms)
Compax3 device:
Cross-section: Minimum... Maximum[mm
sleeve]
M050, M100, M150
0,25 ... 4 (AWG: 23 ... 11)
MP10
Mains supply: 0,5 ... 6 (AWG: 20 ... 10)
Braking resistor: 0,25 ... 4 (AWG: 23 ... 11)
192-120101 N11 C3I11T11 November 2007
2
via a grounding screw at the
Power module
Braking Resistor
Mains supply VAC/PE
Central ground connection for the axis combination,
2
with 10mm
to the ground screw on the housing.
Fan*
Axis controller
Motor / Brake
Fixing for motor shield clamp
Fan*
optinally, the axis controller features a ground screw
on the housing, if the grounding is not possible via the
back plate.
* is internally supplied.
Compax3 device description
2
with contactor
35