C3Sxxx V2; Main Voltage Supply C3S Connector X1 - Parker Compax3S025V2 Operating Instructions Manual

Compax3 i11t11 positioning via digital i/os
Hide thumbs Also See for Compax3S025V2:
Table of Contents

Advertisement

Compax3 device description
3.3.5.

C3Sxxx V2

3.3.5.1
Device protection
28
In this chapter you can read about:

Main voltage supply C3S connector X1.............................................................................................28

Braking resistor / high voltage DC C3S connector X2 .......................................................................29
Main voltage supply C3S connector X1
In this chapter you can read about:
Power supply plug X1 for 1 AC 230VAC/240VAC devices................................................................28
Power supply plug X1 for 3AC 230VAC/240VAC devices.................................................................29
By cyclically switching on and off the power voltage, the input current
limitation can be overloaded, which will cause a device error.
Therefore please wait at least 2 minutes after switching off before you switch
Power supply plug X1 for 1 AC 230VAC/240VAC devices
PIN
Designation
1
L
2
N
3
PE
Mains connection Compax3S0xxV2 1AC
Controller type
Supply voltage
Input current
Maximum fuse rating per device
(=short circuit rating)
Always switch devices off before wiring them!
Dangerous voltages are still present until 5 minutes after
switching off the power supply!
192-120101 N11 C3I11T11 November 2007
the device on again!
S025V2
Single phase 230VAC/240VAC
80-253 VAC/50-60Hz
6Aeff
10 A (circuit breaker
K)
Positioning via digital I/Os
S063V2
13Aeff
16 A (circuit breaker K)