Replacing The Samp On The Avaya S8510 Server; Power Down The Server - Avaya S8510 Manual

Job aids for field replacements (frus)
Hide thumbs Also See for S8510:
Table of Contents

Advertisement

Job Aid: Replacing the SAMP on the Avaya S8510 Server
Avaya Server Availability Management Processor (SAMP): Avaya S8510 Server
(03-602923)

Replacing the SAMP on the Avaya S8510 server

The following S8510 SAMP replacement topics are covered in this section:

Power down the server

Label and disconnect cabling
Remove the S8510 server from the rack
Remove the cover of the S8510 server
Remove the defective SAMP from the S8510 server
Install the replacement SAMP in the S8510 server
Replace the cover on the S8510
Install the replacement S8510 server in the rack
Update the SAMP firmware
Ensure SAMP administration
Return the defective equipment
Power down the server
Shutdown the S8510 server using either the Maintenance Web Pages or the manual Shutdown
button on the faceplate.
1. On the Maintenance Web Pages, select Server > Shutdown Server.
The Shutdown Server page displays.
a. Select the Delayed Shutdown option.
b. Uncheck the Restart server after shutdown checkbox.
c. Click Shutdown.
2. If you cannot access the Maintenance Web Pages, you can manually power down the
server by pressing the power button on the front panel (Note 1 in
front panel
Note:
The system's Advanced Configuration and Power Interface (ACPI) is disabled,
Note:
meaning that power is cut off immediately after pressing the power button.
66 Job Aids for Field Replacements (FRUs) for the Avaya S8510 Server