Tektronix Phaser 550 Service Manual page 39

Hide thumbs Also See for Phaser 550:
Table of Contents

Advertisement

For installations using the printer's Ethernet interface you should
inform the network administrator of the printer's preconfigured
Ethernet address. It is printed on the startup page as well as printed
on a label placed inside the front door.
Does the customer have the appropriate power outlet available? The
printer should be installed on a minimum 15 amp circuit. The
printer's AC power input is ordered for:
110 VAC (87 to 128 VAC)
220 VAC (174 to 250 VAC)
Did the customer order the correct power cord?
_______ U.S. Standard (161-0104-00
_______ European Option A1 (161-0104-06)
_______ United Kingdom Option A2 (161-0066-10)
_______ Australian Option A3 (161-0104-05)
_______ Swiss Option A5 (161-0154-00)
Customers must provide the particular interface cable they need to use
with the printer. Customers can purchase the following from the
Tektronix Graphics Supplies Order Desk by calling 1-800-835-6100.
Parallel cable, DB25 male to Centronics 1284C
Serial, 9-pin to 9-pin, 3 m (10 ft.), null modem
Serial, 9-pin to 25-pin, 3 m (10 ft.), null modem
For AppleTalk installations, customers must provide the appropriate
network adapter to the printer's 9-pin circular LocalTalk connector.
Customers can obtain an adapter from their dealer.
The printer requires the following environmental conditions:
Temperature: 10 to 32.5
Humidity: 10 to 80% relative humidity, non-condensing
Power: 10 A at 110 VAC
6.3 A at 220 VAC
Clearances: A space measuring 107 cm wide by 50 cm deep by 46 cm high
(42 ins. wide by 19.5 ins. deep by 18 ins. high). The width of the printer accounts
for enough clearance to install the paper tray and open the manual feed tray.
Add an additional 23 cm (9 ins) to the height if a lower tray assembly is to be
installed.
Weight support: 39.1 kgs (86.2 lbs.) without the Lower Tray Assembly and
installed consumables. Approximately 53 kgs (117 lbs.) with the Lower Tray
Assembly.
Installing the Printer and Drivers
o
o
C (50 to 91
F)
012-1468-00
012-1379-00
012-1380-00
Service Manual
2-3