Tektronix Phaser 550 Service Manual page 205

Hide thumbs Also See for Phaser 550:
Table of Contents

Advertisement

Table 9-2 Status code meanings (cont'd.)
Status
Front
Binary
State
Panel
Hex
7
. . .
Status - 23
Laser
Scanner
Error
Status
Status - 23
20
0010 0000
Example
Status - 24
Position
Error
Status
Status - 24
01
0000 0001
Example
Meaning/Description
0
This status shows the details of errors that can occur with the laser scanner. This also
relates to the detailed status of Status - 0 Bit 1, Status-1 Bit 1, and Status - 2 Bit 3.
0. Odd parity.
1. Not used.
0 = Always set to 0.
2. 1 = An L-sync short error has occurred.
0 =An L-sync short error has not occurred.
3. 1= An L-sync long error has occurred.
0 = An L-sync error has occurred.
4. 1 = A laser inferiority error has occurred.
0 = Laser power is normal.
5. 1 = The laser scanner motor is not phase locked and is not rotating at the correct speed.
0 = The laser scanner motor speed is correct.
6. Not used.
0 = Always set to 0.
7. 1 = A communication error has occurred.
0 = There is no communication error.
A line sync short error has not occurred.
A line sync overage error has not occurred.
The laser output power is operating normally.
The laser scanning motor is not rotating at its proper speed.
There is no communication error.
This status shows the details of positioning errors associated with the imaging unit belts.
This also relates to the detailed status of Status - 0 Bit 1, Status -1 Bit 1, and
Status - 2 Bit 6
0. Odd parity.
1. 1 = The starting position of the accumulator belt cannot be found.
0 = The positioning of the accumulator belt is normal.
2. 1 = The starting position of the photoconductive belt cannot be found.
0 =The positioning of the photoconductive belt is normal.
3. 1= The movement of the photoconductive belt is asynchronous with the accumulator
belt.
0 = The movement of the photoconductive belt is synchronized with the accumulator be
4. Not used.
0 = Always set to 0.
5. Not used.
0 = Always set to 0.
6. Not used.
0 = Always set to 0.
7. 1 = A communication error has occurred.
0 = There is no communication error.
The positioning of the accumulator belt is operating normally.
The positioning of the photoconductive belt is operating normally.
The photoconductive belt and the accumulator belt are in synchronous operation.
There is no communication error.