HVAC Climate Units - Removal, Replacement And Installation
The connector is supplied with the replacement part.
INSTALLATION
INSTALLING THE OVERHEAT PROTECTION THERMOSTAT / ENGINE COOLANT TEMPERATURE SENSOR
Install the sensors and position the cable harness along the recesses for the heat exchanger. Ensure that the cable
grommet is correctly located in relation to the fan motor cover.
Install the holders for the sensors using 1 screw. Tighten.
Fig. 174: Identifying Cable Terminals And Cables
Courtesy of VOLVO CARS CORPORATION
Install the removed cables together with cable terminals.
- Flame sensor in positions 1 and 2 (blue and brown).
- Glow plug in positions 9 and 12 (white and brown).
- Water pump in positions 10 and 11 (brown and violet).
- Fan motor in positions 13 and 14 (black and brown).