hpe5022_BER_channelIcEndec

C Syntax
ViStatus hpe5022_BER_channelIcEndec(ViSession id, ViBoolean scramble,
ViInt16 blocEndec, ViBoolean precode);
Visual Basic
hpe5022_BER_channelIcEndec(ByVal id As Long, ByVal scramble As Integer,
Syntax
ByVal blocEndec As Integer, ByVal precode As Integer) As Long
Description
This function configures the encoder / decoder functions. The scramble,
modulation and precoding can be specified in this function.
Parameters
• id
Description
Direction
• scramble
Description
Direction
Preset Value
Values
• blocEndec
Description
Direction
Preset Value
Values
Chapter 3
Channel IC Configuration Function
Specifies the system identifier. This is given by the
"hpe5022_init" function.
IN
Selects if the scrambler is activated.
IN
VI_FALSE
Name
Value
VI_TRUE
1
VI_FALSE
0
Specifies the bloc encoding / decoding method.
IN
Depends on the channel IC. See the manual of the channel
IC.
Name
hpe5022_BER_ENDEC_OFF
hpe5022_BER_ENDEC_8_9
hpe5022_BER_ENDEC_16_17
hpe5022_BER_ENDEC_24_25
Function Reference
Description
is active.
Scrambler
is not active.
Scrambler
Value
Description
0
Bypass block
ENDEC
1
8/9
2
16/17
3
24/25
91