Hpe5022_Ber_Burstthreshold - Agilent Technologies E5022B Programming Manual

Hard disk read/write test system
Hide thumbs Also See for E5022B:
Table of Contents

Advertisement

Function Reference
Bit Error Rate Measurement Function

hpe5022_BER_burstThreshold

C Syntax
ViStatus hpe5022_BER_burstThreshold(ViSession id, ViInt16 length, ViInt16
counts);
Visual Basic
hpe5022_BER_burstThreshold(ByVal id As Long, ByVal length As Integer, ByVal
Syntax
counts As Integer) As Long
Description
This function specifies the burst length threshold parameters. This function is only
available for use with the E5039C bit error test module.
Parameters
• id
• length
• counts
144
Description
Specifies the system identifier. This is given by the
"hpe5022_init" function.
Direction
IN
Description
Specifies the burst length threshold in bytes. When
consecutive errors occur for more than 'length' [bytes], this
error block is regarded as a burst error.
Direction
IN
Preset Value
(hpe5022_BER_BURST_LENGTH_THR_MIN)
Values
Name
hpe5022_BER_BURST_LENGTH_THR_MIN
hpe5022_BER_BURST_LENGTH_THR_MAX
Description
Specifies the burst error criterion to count as a lost sector. If
burst occurs more than this value, the sector is considered as
a lost sector. When this value is set to 0, the sector is not
counted as a lost sector even if the burst occurs any number
of times (except that it is an actual lost sector).
Direction
IN
Preset Value
(hpe5022_BER_BURST_COUN_THR_MIN)
Values
Name
hpe5022_BER_BURST_COUN_THR_MIN
hpe5022_BER_BURST_COUN_THR_MAX
Value
1
31
Value
0
4095