Function Reference
BER Data Pattern Definition Function
hpe5022_BER_readGate
C Syntax
ViStatus hpe5022_BER_readGate(ViSession id, ViReal64 trigDelay, ViReal64
aperture);
Visual Basic
hpe5022_BER_readGate(ByVal id As Long, ByVal trigDelay As Double, ByVal
Syntax
aperture As Double) As Long
Description
This function specifies the read gate delay and aperture time. This function is only
available for use with the E5039C bit error test module.
Parameters
• id
• trigDelay
• aperture
72
Description
Specifies the system identifier. This is given by the
"hpe5022_init" function.
Direction
IN
Description
Specifies the read gate delay time in seconds.
Direction
IN
Preset Value
hpe5022_BER_GATE_DEL_MIN
Values
Name
hpe5022_BER_GATE_DEL_MIN
hpe5022_BER_GATE_DEL_MAX
Description
Specifies the read gate aperture time in seconds.
Direction
IN
Preset Value
hpe5022_BER_GATE_APER_MIN
Values
Name
hpe5022_BER_GATE_APER_MIN
hpe5022_BER_GATE_APER_MAX
Value
-9
125 ´ 10
-3
25 ´ 10
Value
-6
1 ´ 10
-3
25 ´ 10