Hpe5022_Ber_Berdataloggingmode - Agilent Technologies E5022B Programming Manual

Hard disk read/write test system
Hide thumbs Also See for E5022B:
Table of Contents

Advertisement

hpe5022_BER_berDataLoggingMode

C Syntax
ViStatus hpe5022_BER_berDataLoggingMode(ViSession id, ViBoolean
sectorData, ViInt16 rawData);
Visual Basic
hpe5022_BER_berDataLoggingMode(ByVal id As Long, ByVal sectorData As
Syntax
Integer, ByVal rawData As Integer) As Long
Description
This function selects the data logging mode. The logging mode is effective for the
"hpe5022_BER_sectorErrorCount_Q" and "hpe5022_BER_errorRawData_Q"
functions.
Parameters
• id
Description
Direction
• sectorData
Description
Direction
Preset value
Values
• rawData
Description
Direction
Preset value
Values
Chapter 3
Bit Error Rate Measurement Function
Specifies the system identifier. This is given by the
"hpe5022_init" function.
IN
Selects the sector data logging mode. This value must be set
to "VI_TRUE" when "hpe5022_BER_sectorErrorCount_Q"
function is used. The "VI_FALSE" makes a measurement
faster.
IN
VI_FALSE
Name
Value
VI_FALSE
0
VI_TRUE
1
Selects the raw data logging mode. This parameter is
effective for the "hpe5022_BER_errorRawData_Q"
function. The
"hpe5022_BER_RAW_DATA_LAST_REV"
makes a measurement faster.
IN
hpe5022_BER_RAW_DATA_ALL (1)
Name
hpe5022_BER_RAW_DATA_ALL
Function Reference
Description
Sector data is not stored.
All sector data is stored.
Value
Description
1
All raw data
is stored.