hpe5022_BER_trackFormat

C Syntax
ViStatus hpe5022_BER_trackFormat(ViSession id, ViInt32 tracPre, ViInt16
sector, ViBoolean gapAuto, ViInt32 gap);
Visual Basic
hpe5022_BER_trackFormat(ByVal id As Long, ByVal tracPre As Long, ByVal
Syntax
sector As Integer, ByVal gapAuto As Integer, ByVal gap As Long) As Long
Description
This function specifies the track format. The track is consisted of the track
preamble, sector and gap. The sector format is defined by the
"hpe5022_BER_sectorFormat" function. The patterns of the track preamble and
gap depends on the read channel IC.
Figure 3-1
Track and Sector Format
Parameters
• id
Description
Direction
• tracPre
Description
Direction
Preset Value
Chapter 3
BER Data Pattern Definition Function
Specifies the system identifier. This is given by the
"hpe5022_init" function.
IN
Specifies the length of the track preamble.
IN
1000