Hpe5022_Ber_Channeliclowpassfilter_Q - Agilent Technologies E5022B Programming Manual

Hard disk read/write test system
Hide thumbs Also See for E5022B:
Table of Contents

Advertisement

hpe5022_BER_channelIcLowPassFilter_Q

C Syntax
ViStatus hpe5022_BER_channelIcLowPassFilter_Q(ViSession id, ViPReal64 fc,
ViPReal64 boost);
Visual Basic
hpe5022_BER_channelIcLowPassFilter_Q(ByVal id As Long, ByRef fc As
Syntax
Double, ByRef boost As Double) As Long
Description
This function returns the cut-off frequency and boost gain of the low pass filter in
the channel IC.
Parameters
• id
Description
Direction
• fc
Description
Direction
Unit
• boost
Description
Direction
Unit
Return Values
Completion Code
VI_SUCCESS
Error Code
hpe5022_ERROR_INV_ID
hpe5022_ERROR_NOT_INIT
See Also
"hpe5022_BER_channelIcLowPassFilter" on page 57
Chapter 3
Channel IC Configuration Function
Specifies the system identifier. This is given by the
"hpe5022_init" function.
IN
Returns the cut-off frequency of the low pass filter.
OUT
Hz
Returns the boost gain of the low pass filter.
OUT
dB
Description
No Error
Description
The handle specified by 'id' is invalid.
The resource of HP E5039A is not
opened at initialize. Check if the HP
E5039A is included in the rsrcArray of
the "hpe5022_init" function.
Function Reference
85

Advertisement

Table of Contents
loading

This manual is also suitable for:

E5023aE5022aE5039cE5039aE5039b

Table of Contents