Function Reference
Bit Error Rate Track Profile Measurement

hpe5022_BER_otcThreshold

C Syntax
ViStatus hpe5022_BER_otcThreshold(ViSession id, ViReal64 otcThr);
Visual Basic
hpe5022_BER_otcThreshold(ByVal id As Long, ByVal otcThr As Double) As
Syntax
Long
Description
This function specifies the threshold level of the bit error rate for OTC (off-track
capability).
Parameters
• id
• otcThr
Return Values
Completion Code
VI_SUCCESS
Error Code
hpe5022_ERROR_INV_ID
hpe5022_ERROR_INV_PARAMETER
hpe5022_ERROR_NOT_INIT
See Also
"hpe5022_BER_otcThreshold_Q" on page 142
"hpe5022_BER_calculateOtc_Q" on page 143
180
Description
Specifies the system identifier. This is given by the
"hpe5022_init" function.
Direction
IN
Description
Specifies the threshold of bit error rate for OTC. The bit
error rate is defined as
Direction
IN
-3
Preset Value
1
10
´
Values
Name
hpe5022_BER_OTC_THR_MIN
hpe5022_BER_OTC_THR_MIN
Value
0
1
Description
No Error
Description
The handle specified by 'id' is invalid.
The parameter 'otcThr' is out of range.
The resource of HP E5039A is not
opened at initialize. Check if the HP
E5039A is included in the rsrcArray of
the "hpe5022_init" function.