Hpe5022_Ber_Setupchannelquality - Agilent Technologies E5022B Programming Manual

Hard disk read/write test system
Hide thumbs Also See for E5022B:
Table of Contents

Advertisement

hpe5022_BER_setupChannelQuality

C Syntax
ViStatus hpe5022_BER_setupChannelQuality(ViSession id, ViInt16 seqType,
ViPObject testHndl);
Visual Basic
hpe5022_BER_setupChannelQuality(ByVal id As Long, ByVal seqType As
Syntax
Integer, ByRef testHndl As Long) As Long
Description
This function assigns the channel quality measurement sequence to the specified
test identifier. See the "hpe5022_BER_measureChannelQuality" function for
details of the sequence. This function does not execute measurement.
Measurement is executed by the "hpe5022_measure" function with the test
identifier specified in this function.
The "hpe5022_BER_channelQuality_Q" function returns the measurement result.
Parameters
• id
Description
Direction
• seqType
Description
Direction
Values
• testHndl
Description
Direction
Return Values
Completion Code
VI_SUCCESS
Error Code
hpe5022_ERROR_INV_ID
hpe5022_ERROR_INV_PARAMETER
Chapter 3
Channel Quality Measurement Function
Specifies the system identifier. This is given by the
"hpe5022_init" function.
IN
Selects the sequence type of BER measurement.
IN
Same as 'seqtype' parameter in the
"hpe5022_BER_measureChannelQuality" function.
Returns the test identifier. This identifier is used to execute
channel quality measurement by the "hpe5022_measure"
function.
OUT
Description
No Error
Description
The handle specified by 'id' is invalid.
The parameter 'seqType' is out of range.
Function Reference
213

Advertisement

Table of Contents
loading

This manual is also suitable for:

E5023aE5022aE5039cE5039aE5039b

Table of Contents