DI–316
10
Check voltage between terminals PTNK and E2 of ECM connectors.
ON
E2 (–)
(1)
NG
11
Check for open and short in harness and connector between vapor pressure
sensor and ECM (See page IN–31).
OK
Replace vapor pressure sensor.
DIAGNOSTICS
PTNK (+)
(2)
Vacuum
A02025
–
ENGINE (1MZ–FE)
PREPARATION:
(a)
Remove the glove compartment (See page SF–73).
(b)
Turn the ignition switch ON.
CHECK:
Measure voltage between terminals PTNK and E2 of the ECM
connectors.
(1)
Disconnect the vacuum hose from the vapor pres-
sure sensor.
(2)
Using the MITYVAC (Hand–Held Vacuum Pump),
apply a vacuum of 4.0 kPa (30 mmHg, 1.18 in.Hg)
to the vapor pressure sensor.
NOTICE:
The vacuum applied to the vapor pressure sensor must be
less than 66.7 kPa (500 mmHg, 19.7 in.Hg).
OK:
(1) Voltage: 2.9 ∼ 3.7 V
(2) Voltage: 0.5 V or less
OK
Go to step 12.
NG
Repair or replace harness or connector.
Author :
Date :
551