Toyota Camry Manual page 927

Hide thumbs Also See for Camry:
Table of Contents

Advertisement

CH–10
Length
Positive (+)
Ohmmeter
Terminal
Ohmmeter
CHARGING (1MZ–FE)
3.
Using a vernier caliper, measure the exposed brush length.
If the exposed length is less than minimum, replace the brushes
and brush holder assembly.
P13535
4.
(a)
Rectifire
Terminal
P00480
If continuity is not as specified, replace the rectifier holder.
(b)
Negative (–)
Treminal
If continuity is not as specified, replace the rectifier holder.
P00481
5.
Check the bearing is not rough or worn.
If necessary, replace the bearing. (See page CH–11)
GENERATOR
INSPECT BRUSHES
Standard exposed length: 10.5 mm (0.413 in.)
Minimum exposed length: 1.5 mm (0.059 in.)
INSPECT RECTIFIERS (RECTIFIRE HOLDER)
Check the positive (+) rectifire.
(1)
Using an ohmmeter, connect one tester probe to the
positive (+) terminal and the other to each rectifier
terminal.
(2)
Reverse the polarity of the tester probes and repeat
step (a).
(3)
Check that one shows continuity and the other
shows no continuity.
Check the negative (–) rectifire.
(1)
Using an ohmmeter, connect one tester probe to
each negative (–) terminal and the other to each
rectifier terminal.
(2)
Reverse the polarity of the tester probes and repeat
step (a).
(3)
Check that one shows continuity and the other
shows no continuity.
INSPECT BEARING