Electronic Control Module - Remove And Install - Perkins 1106D Disassembly And Assembly

Industrial engine
Table of Contents

Advertisement

170
Disassembly and Assembly Section
Illustration 345
1. Remove the setscrews (1) from the fan drive (2).
Note: Identify the orientation and the position of the
fan drive.
2. Remove the fan drive (2).
Installation Procedure
Illustration 346
1. Check the fan drive for wear or damage. If the fan
drive is worn or damaged, replace the fan drive.
2. Install the fan drive (2).
3. Install the setscrews (1). Tighten the setscrews to
a torque of 44 N·m (32 lb ft).
End By:
a. Install the fan. Refer to Disassembly and Assembly
Manual, "Fan - Remove and Install".
Electronic Control Module -
Remove and Install
Removal Procedure
Ensure that all adjustments and repairs that are
carried out to the fuel system are performed
by authorized personnel that have the correct
training.
g00944500
Before begining ANY work on the fuel system,
refer to Operation and Maintenance Manual,
"General Hazard Information and High Pressure
Fuel Lines" for safety information.
Refer to Testing and Adjusting Manual,
"Cleanliness of Fuel System Components"
for detailed information on the standards of
cleanliness that must be observed during ALL
work on the fuel system.
1. Isolate the electrical supply to the engine.
2. Isolate the fuel supply to the engine.
g00944500
Illustration 347
Typical example
SENR9983
i02296737
g01202267

Advertisement