5
UTILITY PACKAGE (GX Configurator-DA)
5.6.3
[Purpose]
[Operating procedure]
[Setting screen]
[Explanation of items]
(1) Items
(2) Setting details
5
- 25
5.6 Monitoring/Test

5.6.3 Confirmation of Conversion Characteristic

Confirmation of Conversion Characteristic
The converted value of digital-analog conversion can be confirmed according to the
tilt of the graph, based on the offset/gain setting.
Monitor/Test screen
I/O characteristic diagram: Displays the I/O conversion characteristic to the prepared
offset/gain setting.
Analog and Range setting
Analog:
Range setting:
Offset/Gain setting
Offset value:
Gain value:
Select the output (voltage/current) when a digital value is
converted to an analog value.
Select either "User range setting 2" or "User range setting
3. " However, if "Current" is selected for the "Analog" item,
only "User range setting 1" can be selected.
Enter an offset value to display the I/O characteristic dia-
gram.
Enter a gain value to display the I/O characteristic diagram.