4
SETUP AND PROCEDURES BEFORE OPERATION
(b) When switching the mode using the setting of the mode switching setting
2
Normal mode initial setting
Switches to offset/gain setting mode
Switches to normal mode
(c) When switching the mode by making intelligent function module switch setting
(Un\G158, Un\G159) and operation condition setting request (Y9)
3
Adding initial setting items
Common program
When running this program together with the normal-mode D/A conversion program(shown
in Section 6.2.3), use *2 of this program as the initial setting program.
Note)When adding this program to the normal-mode D/A conversion program (shown
inSection 6.2.3), replace the existing initial setting program with the programmarked *2
*3 Example of adding initial setting items (Rate control funcion)
Only the common program is necessary.
\
D/A conversion enable/disable
setting
Turns ON operation condition
setting request (Y9).
\
Sets 4144H to buffer memory
address 158.
\
Sets 964H to buffer memory
address 159.
Turns ON operation condition
setting request (Y9).
\
Sets 964H to buffer memory
address 158.
\
Sets 4144H to buffer memory
address 159.
Turns ON operation condition
setting request (Y9).
Turns OFF operation condition
setting request (Y9).
1-second timer
\
Rate control
enable/disable setting
\
CH1 increase digital
limit value
\
CH1 decrease digital
limit value
4.6 Offset/Gain Settings
1
2
3
4
5
6
7
8
4
- 15