Mitsubishi MELSEC-Q series User Manual page 78

Gx configurator-da. channel isolated digital-analog converter module
Hide thumbs Also See for MELSEC-Q series:
Table of Contents

Advertisement

5
UTILITY PACKAGE (GX Configurator-DA)
(5) Switching between two or more Intelligent function module utilities
(6) Number of parameters that can be set in GX Configurator-DA
5
- 3
5.2 Installing and Uninstalling the Utility Package
5.2.1 Handling precautions
When two or more Intelligent function module utility screens cannot be displayed side
by side, select a screen to be displayed on the top of others using the task bar.
When multiple intelligent function modules are mounted, the number of parameter
settings must not exceed the following limit.
When intelligent function modules are installed to:
Q00J/Q00/Q01CPU
Q02/Q02H/Q06H/Q12H/Q25HCPU
Q02PH/Q06PH/Q12PH/Q25PHCPU
Q12PRH/Q25PRHCPU
Q02UCPU
Q03UD/Q04UDH/Q06UDH/Q13UDH/Q26UDH/
Q03UDE/Q04UDEH/Q06UDEH/Q13UDEH/
Q26UDEHCPU
MELSECNET/H remote I/O station
For example, if multiple intelligent function modules are installed to the MELSECNET/
H remote I/O station, configure the settings in GX Configurator so that the number of
parameter settings for all the intelligent function modules does not exceed the limit of
the MELSECNET/H remote I/O station.
Calculate the total number of parameter settings separately for the initial setting and
for the auto refresh setting.
The number of parameters that can be set for one module in GX Configurator-DA is
as shown below.
Target module
Q66DA-G
Example) Counting the number of parameter settings in Auto refresh setting
Maximum number of parameter settings
Initial setting
512
512
512
512
2048
4096
512
Initial setting
5 (Fixed)
This one row is counted as one setting.
Blank rows are not counted.
Count up all the setting items on this screen, and
add the total to the number of settings for other
intelligent function modules to get a grand total.
Auto refresh setting
256
256
256
256
1024
2048
256
Auto refresh setting
14 (Max.)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q66da-g

Table of Contents